- Technical
Performance
Sym-Wall® is a robust, high performance, eco-friendly building module designed to replace traditional dry-wall (plasterboard & stud) and block-work for internal partition and party wall applications.
The panel is currently applied as a non-load bearing element for walls and as a structural cavity-reinforced plank for mezzanine and party floors. The company plans to certify the panel for structural applications in 2016.
The performance of the Sym-Wall® variants is summarized as follows:
Fire (BS EN 1364-1:1999)
SW100 – Partition Wall Configuration (single panel)
Insulation Criterion – 89 Minutes
Integrity Criterion – Sustained Flaming – 120 minutes, no failure
Acoustic (BS EN ISO 10140-2:2010)
SW100 – Partition Wall Configuration (single panel)
Weighted Airborne Sound Reduction Index – RW (C; Ctr) 31 (-1; -2) dB
SW100 – Party Wall Configuration (2 panels separated by 50mm gap – 250mm wall thickness)
Weighted Airborne Sound Reduction Index – RW (C; Ctr) 46 (-1; -3) dB
Mechanical (BS 5234: Part 2:1992) – Medium Duty Testing Level
SW100 – Partition Wall Configuration (single panel)
Annex A – Partition Stiffness – Pass
Annex B – Small Hard Body Impact – Pass
Annex C – Large Soft Body Impact – Pass
Annex D – Small Hard Body Impact – Pass
Annex E – Multiple Impact from Large Soft Body – Pass
Thermal Insulation
SW100ins - Party Wall Configuration – (2 panels separated by 50mm gap – 250mm wall thickness)
U-Value – 0.15 W/m2.K (based on cavity infill having thermal conductivity, k = 0.028 W/m.K)
Sym-Shield™ - Insulated Party Wall Configuration with applied surface coating of ThermoShield® intelligent IR reflecting paint system
Combined U-Value – 0.12 W/m2.K (analytical value, to be confirmed)
Water Uptake Performance
SW100res - ≤ 5% uptake by weight after 72 hours of total immersion in water
Loading
SW100F – Floor Plank
Suitable for point and distributed residential loading levels applicable to mezzanine and party flooring (enquire for more technical information)